How to configure an ioSmart reader on the operation tab

You can also configure the ioSmart reader on the operation tab.

  1. On the EntraPass workstation, click Operation.
  2. Click Controller.
  3. In the Connection pane, select the appropriate device.
  4. In the Controller pane, right-click the controller, and click Request unassigned modules.
  5. Right-click a controller and click Unassigned Module. This creates a Controller unassigned module requested by operator event on the desktop.
  6. Right-click the event to assign the ioSmart reader. The serial number of the ioSmart reader is automatically filled on the Configuration tab.
  7. Optional: To view the status of the configured ioSmart reader, on the EntraPass workstation, click Operation, and click Door. In the Door pane, right-click the appropriate door.
  8. Optional: To view the status of all configured ioSmart readers that are connected to a controller, on the EntraPass workstation, click Operation, and click Controller.